Espesyal na Teknolohiya ng Air CompressorParameter At Mga Mode (WQC)
Uri | kapangyarihan | Boltahe | Na-rate ang kasalukuyang | Ang bahagi ng thermal relay ay naayos na saklaw |
WQC-12 | 0.75KW | 380V | 2.1A | 1.7-2.5A |
WQC-12 | 1.1KW | 380V | 2.5A | 2-3A |
WQC-12 | 1.5KW | 380V | 3.6A | 2.8-4.4A |
WQC-12 | 2.2KW | 380V | 5A | 4-6A |
WQC-12 | 3KW | 380V | 6.6A | 5.2-8A |
WQC-32 | 4KW | 380V | 9A | 7-11A |
WQC-32 | 5.5KW | 380V | 11A | 9-13A |
WQC-32 | 7.5KW | 380V | 15A | 12-18A |
WQC-32 | 11KW | 380V | 22A | 20-32A |
WQC-50 | 15KW | 380V | 30A | 28-45A |
WQC-50 | 18.5KW | 380V | 37A | 40-63A |
WQC-65 | 18.5KW | 380V | 37A | 40-63A |
WQC-85 | 22KW | 380V | 44A | 40-63A |
WQC-95 | 30KW | 380V | 60A | 53-85A |
Uri | Contactor | Karaniwang thermal relay | Kontrolin ang lakas ng motor (KW) | Rated kasalukuyang (A) | ||||
Uri | Nakatakdang kasalukuyang | 220V | 380V | 500V | 220V | 380V | ||
QCX5-9 | CJX5-9 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 11 | 9 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 11A | 3 | 5.5 | 7.5 | 13 | 12 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 29A | 7.5 | 15 | 18.5 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 35A | 9 | 18.5 | 22 | 40 | 40 |
Dimensyon at Pag-mount Dimensyon
■ Maaaring matagal ang starter at hindi gumagana ang thermal relay. Ang dalas ay maaaring 600 beses/oras sa maikling panahon at paulit-ulit na gumagana;
■ Ang akit na coil ay maaaring mapagkakatiwalaang gumana kapag 85%~105% rated boltahe, Ito ay inilabas boltahe humigit-kumulang ay 40~55% rated boltahe;
■ Ang starter contact sa operating frequency ay 600/hours, ang pabilog na telegrama ay patuloy na nangunguna para sa merito na 40%.Puts through the nominal current put through, kapag separation ang factor ay 0.35, Ito ay electrical life is not lower than 640,000 times;
■ Ang mekanikal na buhay ng starter ay 3 milyong beses;
■ Ang auxiliary contact ng starter, ang nominal na kasalukuyang ay 5A;
■ Ang thermal relay ay may organisasyon ng kompensasyon sa temperatura, Maaaring balansehin ang temperatura na sanhi ng mga pagbabago ng boltahe na nakapalibot na temperatura;
■ Ang sobrang karga ng thermal relay ay kasama ng mga itinatakda. Upang makita ang mga sumusunod.